<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Harmonics &#8211; Electrical India Magazine</title>
	<atom:link href="https://www.electricalindia.in/category/power/harmonics/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.electricalindia.in</link>
	<description></description>
	<lastBuildDate>Thu, 15 Jun 2023 04:17:56 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.5</generator>

<image>
	<url>https://www.electricalindia.in/wp-content/uploads/2022/08/cropped-EI_favicon-1-32x32.png</url>
	<title>Harmonics &#8211; Electrical India Magazine</title>
	<link>https://www.electricalindia.in</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Effect of TRANSFORMERS Saturation</title>
		<link>https://www.electricalindia.in/effect-of-transformers-saturation/</link>
					<comments>https://www.electricalindia.in/effect-of-transformers-saturation/#respond</comments>
		
		<dc:creator><![CDATA[Editor, Chary Publications]]></dc:creator>
		<pubDate>Thu, 15 Jun 2023 04:17:56 +0000</pubDate>
				<category><![CDATA[Harmonics]]></category>
		<category><![CDATA[Others]]></category>
		<category><![CDATA[Power]]></category>
		<category><![CDATA[Transformers]]></category>
		<guid isPermaLink="false">https://www.electricalindia.in/?p=20170</guid>

					<description><![CDATA[A transformer can incur in core saturation conditions in either of the following cases: When operating above rated power When operating above rated voltage The first situation can arise during peak demand periods, and the second case can occur during light load conditions, especially if utility capacitor banks are not disconnected accordingly and the feeder [&#8230;]]]></description>
		
					<wfw:commentRss>https://www.electricalindia.in/effect-of-transformers-saturation/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>PHOTOVOLTAIC-FED MULTILEVEL INVERTER</title>
		<link>https://www.electricalindia.in/photovoltaic-fed-multilevel-inverter/</link>
					<comments>https://www.electricalindia.in/photovoltaic-fed-multilevel-inverter/#respond</comments>
		
		<dc:creator><![CDATA[Editor, Chary Publications]]></dc:creator>
		<pubDate>Fri, 05 Feb 2021 06:30:35 +0000</pubDate>
				<category><![CDATA[Emergency Power]]></category>
		<category><![CDATA[Featured]]></category>
		<category><![CDATA[Harmonics]]></category>
		<category><![CDATA[Others]]></category>
		<category><![CDATA[Power]]></category>
		<category><![CDATA[Renewables]]></category>
		<category><![CDATA[Solar]]></category>
		<guid isPermaLink="false">https://www.electricalindia.in/?p=16205</guid>

					<description><![CDATA[The quality of power is most significant in the field of the power system. Many techniques are used for improving the same. In this article, the quality of the Power and THD values for different switching pulses are to be analyzed. Here, the existing system comprises a Solar Photovoltaic array, boost converter, Multilevel inverter with normal switching pulse, and RLC Load. The proposed system comprises a solar photovoltaic array fed multilevel inverter with Pseudorandom Binary Switching (PRBS) pulse, buck-boost converter, and three-phase induction motor. The Pseudo-Random Binary Sequence generator consists of shift register and logic gates...]]></description>
		
					<wfw:commentRss>https://www.electricalindia.in/photovoltaic-fed-multilevel-inverter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Stator Earth Fault Protection for Generators</title>
		<link>https://www.electricalindia.in/stator-earth-fault-protection-for-generators/</link>
					<comments>https://www.electricalindia.in/stator-earth-fault-protection-for-generators/#respond</comments>
		
		<dc:creator><![CDATA[Editor, Chary Publications]]></dc:creator>
		<pubDate>Fri, 05 Apr 2019 09:14:17 +0000</pubDate>
				<category><![CDATA[Featured]]></category>
		<category><![CDATA[Harmonics]]></category>
		<category><![CDATA[Power]]></category>
		<category><![CDATA[Safety]]></category>
		<guid isPermaLink="false">https://www.electricalindia.in/?p=8033</guid>

					<description><![CDATA[The article reveals that 3rd Harmonic voltage generation is prime criterion to deploy the 100 per cent Stator Earth fault protection. - Dinesh Pawar


]]></description>
		
					<wfw:commentRss>https://www.electricalindia.in/stator-earth-fault-protection-for-generators/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Which factors affect the power supply quality?</title>
		<link>https://www.electricalindia.in/which-factors-affect-the-power-supply-quality/</link>
					<comments>https://www.electricalindia.in/which-factors-affect-the-power-supply-quality/#respond</comments>
		
		<dc:creator><![CDATA[Editor, Chary Publications]]></dc:creator>
		<pubDate>Tue, 05 Mar 2019 09:19:28 +0000</pubDate>
				<category><![CDATA[Featured]]></category>
		<category><![CDATA[Harmonics]]></category>
		<category><![CDATA[Power]]></category>
		<category><![CDATA[T&D]]></category>
		<guid isPermaLink="false">https://www.electricalindia.in/?p=7586</guid>

					<description><![CDATA[The harmonious and uniform standards should be specified by the State Regulatory Commissions to serve the best interest of the utilities and consumers connected to the national grid. - Ashok Upadhyay


]]></description>
		
					<wfw:commentRss>https://www.electricalindia.in/which-factors-affect-the-power-supply-quality/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Curbing Harmonics using Apparent Energy Metering</title>
		<link>https://www.electricalindia.in/curbing-harmonics-using-apparent-energy-metering/</link>
					<comments>https://www.electricalindia.in/curbing-harmonics-using-apparent-energy-metering/#comments</comments>
		
		<dc:creator><![CDATA[Editor, Chary Publications]]></dc:creator>
		<pubDate>Sat, 05 Jan 2019 08:25:08 +0000</pubDate>
				<category><![CDATA[Featured]]></category>
		<category><![CDATA[Harmonics]]></category>
		<category><![CDATA[Instrumentation]]></category>
		<category><![CDATA[Power]]></category>
		<guid isPermaLink="false">http://www.electricalindia.in/?p=6943</guid>

					<description><![CDATA[The article explains how an electrical revolution can be effectively triggered - where market sees rapid sales of efficient electrical appliances. - P. Chaitanyasreerama, Dr. Vithal N. Kamat



]]></description>
		
					<wfw:commentRss>https://www.electricalindia.in/curbing-harmonics-using-apparent-energy-metering/feed/</wfw:commentRss>
			<slash:comments>1</slash:comments>
		
		
			</item>
		<item>
		<title>Improved Power Quality &#038; Reduced Harmonics</title>
		<link>https://www.electricalindia.in/improved-power-quality-reduced-harmonics/</link>
					<comments>https://www.electricalindia.in/improved-power-quality-reduced-harmonics/#respond</comments>
		
		<dc:creator><![CDATA[Editor, Chary Publications]]></dc:creator>
		<pubDate>Mon, 05 Mar 2018 07:06:03 +0000</pubDate>
				<category><![CDATA[Harmonics]]></category>
		<category><![CDATA[Power]]></category>
		<guid isPermaLink="false">http://www.electricalindia.in/?p=1887</guid>

					<description><![CDATA[An increasing number of loads are non-linear, introducing harmonics into the power grid and thus significantly impairing the power quality. EPCOS PQSine™ is an active harmonic filter that effectively reduces the unwanted harmonics…]]></description>
		
					<wfw:commentRss>https://www.electricalindia.in/improved-power-quality-reduced-harmonics/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Harmonics in Power System</title>
		<link>https://www.electricalindia.in/harmonics-in-power-system-2/</link>
					<comments>https://www.electricalindia.in/harmonics-in-power-system-2/#comments</comments>
		
		<dc:creator><![CDATA[Editor, Chary Publications]]></dc:creator>
		<pubDate>Fri, 05 Jan 2018 09:53:22 +0000</pubDate>
				<category><![CDATA[Harmonics]]></category>
		<category><![CDATA[Power]]></category>
		<guid isPermaLink="false">http://www.electricalindia.in/?p=1801</guid>

					<description><![CDATA[The distribution of the harmonic sources requires close monitoring between OEM &#038; users for making a stringent specification in order to minimize voltage-distortion levels are kept to acceptable levels on the overall system considering IEEE 519- standards...

]]></description>
		
					<wfw:commentRss>https://www.electricalindia.in/harmonics-in-power-system-2/feed/</wfw:commentRss>
			<slash:comments>1</slash:comments>
		
		
			</item>
		<item>
		<title>Analysis And Elimination Of Third Harmonics</title>
		<link>https://www.electricalindia.in/analysis-and-elimination-of-third-harmonics/</link>
					<comments>https://www.electricalindia.in/analysis-and-elimination-of-third-harmonics/#respond</comments>
		
		<dc:creator><![CDATA[Editor, Chary Publications]]></dc:creator>
		<pubDate>Mon, 05 Dec 2016 11:55:24 +0000</pubDate>
				<category><![CDATA[Harmonics]]></category>
		<category><![CDATA[Power]]></category>
		<guid isPermaLink="false">http://www.electricalindia.in/?p=4174</guid>

					<description><![CDATA[This article discusses the power quality issues and how is the unwanted component (called harmonic) introduced. Consequence of harmonics according to their sequence will be different and most precarious also. Moreover, different strategies according to different cases are discussed. We have discussed four different cases. Whereever necessary, the mathematical analysis is shown with output waveform to prove the arguments... - Paresh Modha, Minesh Joshi]]></description>
		
					<wfw:commentRss>https://www.electricalindia.in/analysis-and-elimination-of-third-harmonics/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Managing 12 Pulse Converters</title>
		<link>https://www.electricalindia.in/managing-12-pulse-converters/</link>
					<comments>https://www.electricalindia.in/managing-12-pulse-converters/#respond</comments>
		
		<dc:creator><![CDATA[Editor, Chary Publications]]></dc:creator>
		<pubDate>Mon, 05 Sep 2016 08:58:08 +0000</pubDate>
				<category><![CDATA[Harmonics]]></category>
		<category><![CDATA[Power]]></category>
		<guid isPermaLink="false">http://www.electricalindia.in/?p=4441</guid>

					<description><![CDATA[This article discusses 12 Pulse Converter Circuitry commonly found in Variable Speed Drives. The simulation of 12 pulse converters performs in both the Balanced and Unbalanced condition of Line voltages as well as frequency... - Minesh K. Joshi, Paresh Modha, Paresh Modha, Jigar N. Mistry, Mitesh B. Astik]]></description>
		
					<wfw:commentRss>https://www.electricalindia.in/managing-12-pulse-converters/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Harmonics Causes &#038; Effects</title>
		<link>https://www.electricalindia.in/harmonics-causes-effects/</link>
					<comments>https://www.electricalindia.in/harmonics-causes-effects/#comments</comments>
		
		<dc:creator><![CDATA[Editor, Chary Publications]]></dc:creator>
		<pubDate>Fri, 05 Aug 2016 10:42:44 +0000</pubDate>
				<category><![CDATA[Harmonics]]></category>
		<category><![CDATA[Power]]></category>
		<guid isPermaLink="false">http://www.electricalindia.in/?p=4497</guid>

					<description><![CDATA[Harmonics are defined as the content of signal whose frequency is an integral multiple of the system frequency of the fundamental. Voltage distortion is generally very harmful because it can increase the effective peak value and also the rms current in some devices connected to the network... - Basant Kumar]]></description>
		
					<wfw:commentRss>https://www.electricalindia.in/harmonics-causes-effects/feed/</wfw:commentRss>
			<slash:comments>1</slash:comments>
		
		
			</item>
		<item>
		<title>AT &#038; C Loss Reduction</title>
		<link>https://www.electricalindia.in/at-c-loss-reduction/</link>
					<comments>https://www.electricalindia.in/at-c-loss-reduction/#respond</comments>
		
		<dc:creator><![CDATA[Editor, Chary Publications]]></dc:creator>
		<pubDate>Tue, 05 Apr 2016 11:18:58 +0000</pubDate>
				<category><![CDATA[Harmonics]]></category>
		<category><![CDATA[Power]]></category>
		<category><![CDATA[T&D]]></category>
		<guid isPermaLink="false">http://www.electricalindia.in/?p=4859</guid>

					<description><![CDATA[A T &#038; C loss is nothing but the sum total of technical and commercial losses and shortage due to non-realisation of billed amount... - Robbin Pramanick]]></description>
		
					<wfw:commentRss>https://www.electricalindia.in/at-c-loss-reduction/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Lighting Systems And Their Effect On Power Quality</title>
		<link>https://www.electricalindia.in/lighting-systems-and-their-effect-on-power-quality/</link>
					<comments>https://www.electricalindia.in/lighting-systems-and-their-effect-on-power-quality/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sat, 05 Sep 2015 09:12:01 +0000</pubDate>
				<category><![CDATA[Harmonics]]></category>
		<category><![CDATA[Lighting]]></category>
		<category><![CDATA[Others in Lighting Industry]]></category>
		<category><![CDATA[Power]]></category>
		<guid isPermaLink="false">https://www.ei.electricalindia.in/?p=5901</guid>

					<description><![CDATA[Poor power quality management inevitably leads to an increase in operational costs and places an unnecessary strain on already dwindling resources. The ultimate reason that we are interested in power quality is economic value... - Dr. K Uma Rao, Nitish N, Pramod R Rao, Ashish M Rao]]></description>
		
					<wfw:commentRss>https://www.electricalindia.in/lighting-systems-and-their-effect-on-power-quality/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>An ANN Based Approach For Optimal Placement Of Custom Power Devices</title>
		<link>https://www.electricalindia.in/an-ann-based-approach-for-optimal-placement-of-custom-power-devices/</link>
					<comments>https://www.electricalindia.in/an-ann-based-approach-for-optimal-placement-of-custom-power-devices/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 05 Aug 2015 12:21:29 +0000</pubDate>
				<category><![CDATA[Case Studies]]></category>
		<category><![CDATA[Harmonics]]></category>
		<category><![CDATA[Power]]></category>
		<category><![CDATA[Power Electronics]]></category>
		<guid isPermaLink="false">https://www.ei.electricalindia.in/?p=5990</guid>

					<description><![CDATA[Power electronics based controllers used in distribution systems are called custom power devices. These devices have been proved to be quite effective in power quality enhancement. They may be of series, shunt and series-shunt or series-series type – depending upon their connection in the circuit... - D K Tanti, MK Verma, Brijesh Singh, O N Mehrotra]]></description>
		
					<wfw:commentRss>https://www.electricalindia.in/an-ann-based-approach-for-optimal-placement-of-custom-power-devices/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Performance Evaluation</title>
		<link>https://www.electricalindia.in/performance-evaluation/</link>
					<comments>https://www.electricalindia.in/performance-evaluation/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Fri, 05 Jun 2015 06:51:06 +0000</pubDate>
				<category><![CDATA[Allied Products]]></category>
		<category><![CDATA[Capacitors & Condensers]]></category>
		<category><![CDATA[Emergency Power]]></category>
		<category><![CDATA[Harmonics]]></category>
		<category><![CDATA[Power]]></category>
		<guid isPermaLink="false">https://www.ei.electricalindia.in/?p=6196</guid>

					<description><![CDATA[In previous publications, authors have reported about the performance of the single-phase inverter topology based on controlled charging of the capacitor. The dynamic performance was not available. This article presents the dynamic performance of the inverter for various types of load, which includes leading, lagging and unity power factor, and analysis for 'total harmonic distortion' has been included... - K.Vijayakumar, S.Kannan and S.Ponnayira Sundaravel]]></description>
		
					<wfw:commentRss>https://www.electricalindia.in/performance-evaluation/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Distribution System Capacitor Banks And their Impact On Power Quality</title>
		<link>https://www.electricalindia.in/distribution-system-capacitor-banks-and-their-impact-on-power-quality/</link>
					<comments>https://www.electricalindia.in/distribution-system-capacitor-banks-and-their-impact-on-power-quality/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 05 May 2015 10:34:52 +0000</pubDate>
				<category><![CDATA[Allied Products]]></category>
		<category><![CDATA[Capacitors & Condensers]]></category>
		<category><![CDATA[Harmonics]]></category>
		<category><![CDATA[Power]]></category>
		<guid isPermaLink="false">https://www.ei.electricalindia.in/?p=6268</guid>

					<description><![CDATA[The most common solution to harmonic problems involves the application of harmonic filters. Capacitors and the system short-circuit impedance combine to create resonances that can magnify harmonic levels to well above accepted limits. What is the solution? - Dr L Ashok Kumar]]></description>
		
					<wfw:commentRss>https://www.electricalindia.in/distribution-system-capacitor-banks-and-their-impact-on-power-quality/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
